You Searched For: Gas Inlet Tubes
395 results were found
Solvac Mobile Phase Filtration
/cms/solvac_mobile_phase_filtration
Solvac Mobile Phase Filtration Solvac Mobile phase filtration is a vital aid for ensuring the quality and reproducibility of your results by removing particulates and gas and stabilising the baseline. The easy-to-use device gives huge time cost an...
Rotameter—Variable Area Flowmeter Technical Information
/cms/tech_article_valve_selection_guide
Rotameter—Variable Area Flowmeter Technical Information Important Information on Rotameters The Variable-Area type flowmeter or Rotameter is one of the most economical and reliable of flow measurement instruments. In various configurations flow me...
Gas Regulators
/cms/B392558CE2BB40ED9827EDADA26A43C0
Gas Regulators High-Purity Single-Stage Regulators Chrome-Plated Brass or 316 Stainless Steel These high-purity single-stage regulators are ideally suited for primary pressure control of noncorrosive high-purity gases (chrome-plated brass) or corr...
Pumping Viscous Fluids
/cms/tech-article-pumping-viscous-fluids
Pumping Viscous Fluids Viscous fluids flow much slower than water-like fluids for several reasons including: The fluid is more resistant to flow than water. There are greater frictional forces between the wall of the tubing and a viscous fluid tha...
Hichrom Catalogue 9
/m-ni.vwr.com/en_NI/images/CONSUMABLES_and_ACCESSORIES-Filters_p335-336.pdf
Hichrom Catalogue 9 HICHROM Chromatography Columns and Supplies Hichrom Limited 1 The Markham Centre Station Road Theale Reading Berks RG7 4PE UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email: sales@hichrom.co.uk www.hichrom.co.uk Catalo...
How to Reduce Pulsation in Peristaltic Pumping Systems | Avantor
/cms/tech-article-reducing-pulsation-peristaltic-pumping
How To Reduce Pulsation in Peristaltic Pumps Some applications for peristaltic pumps are sensitive to pulsating fluid flow. Fortunately there are many things you can do to help reduce the adverse effects of pulsation. The following topics will be ...
Cavity Style vs. Suction Shoe Style Pump Heads
/cms/tech_article_cavity_style_vs_suction_shoe_style_pump_heads
Cavity Style vs. Suction Shoe Style Pump Heads Pump-head design comparison for gear pumps This article discusses the differences between the cavity style and the suction shoe pump heads for gear pumps. Pump heads for gear pumps are available as wi...
Valve Selection Guide
/cms/tech-article-valve-selection-guide
Valve Selection Guide Valve Terms Breaking Pressure: The minimum pressure required to produce flow through a valve. Duty Cycle: 100% duty cycle is defined as continuous operation without any damage occurring. For intermittent duty cycle (<100%) al...
How to Load Tubing into Masterflex I/P High-Perfomance Peristaltic Pumps
/cms/tech-article-masterflex-i-p-tube-loading
How to Load Tubing into Masterflex I/P High-Perfomance Peristaltic Pumps To view this video please enable JavaScript and consider upgrading to a web browser that supports HTML5 video Tubing Loading Steps This video shows how to load tubing into a ...
Sampling Solutions
/cms/sampling_solutions
Sampling Solutions Exact Volume Sampling Solutionss New aseptic and accurate sampling solutions from Avantor designed for your high value critical samples are flexible and scalable while reducing contamination risk. What fluid handling solution ca...
Flowmeter FAQs
/cms/tech-article-flowmeter-faqs
Flowmeter FAQs Single-Use Flowmeter How do the Masterflex® flowmeters work? Which single-use sensor type makes the most sense for my application? What accuracy level can I expect to achieve with each sensor type? Can these sensors be used with opa...
VacuCap® Vacuum Filtration Devices
/cms/13C6862508D2478186283685DF783D2D
VacuCap® Vacuum Filtration Devices VacuCap® Vacuum Filtration Devices Innovative bottle-top filters can fill multiple bottles with one device Ability to process 100 mL to 5L volumes into multiple aliquots Reduces storage space and waste Environmen...
PHARMED Tubing
/cms/tech-article-pharmed-tubing
PHARMED Tubing Advantages: Great for tissue and cell worknontoxic and nonhemolytic. Long service life minimizes risk of fluid exposure; reduces tubing costs and pump downtime. Opaque to UV and visible light to protect light-sensitive fluids. Heat...
Optimising GC method development
/cms/optimising_gc_method
Optimising GC method development Webinar Monday 21st November 2022 15:00 to 16:00 CET (Berlin Paris Madrid) Replay Email Alerts Free Registration Chat Area Certificate of attendance When developing GC methods numerous variables require careful con...
Viton Tubing Specifications
/cms/tech-article-viton-tubing
Viton Tubing Specifications Advantages: Our most chemical-resistant tubing. Resistant to corrosives solvents and oils at elevated temperature. Low gas permeability. Limitations: Limited pumping life. Application Suitability: Acids: Excellent Alkal...
BioPharm Silicone Tubing
/cms/tech-article-biopharm-silicone-tubing
BioPharm Silicone Tubing Advantages: Ultra-smooth inner surface. Minimizes particle entrapment. Lower absorption; excellent biocompatibility; no leachable additives DOP or plasticizers. Odorless and nontoxic fungus resistant. No taste imparted to ...
1 - 16 of 395