Toluene ≥99.7% (by GC, corrected for water content), ULTRA RESI-ANALYZED® for organic residue analysis, J.T.Baker®
Supplier: Avantor
|
Danger
|
Synonyms:
Methylbenzene, Phenylmethane, FM approval
Packaged under inert gas.
9336.1000EA
111
GBP
9336.1000
9336.2500
9336-03
Toluene ≥99.7% (by GC, corrected for water content), ULTRA RESI-ANALYZED® for organic residue analysis, J.T.Baker®
Toluene
Formula:
C₆H₅CH₃ MW: 92,14 g/mol Boiling Pt: 110,6 °C (1013 hPa) Melting Pt: –95 °C Density: 0,867 g/cm³ (20 °C) Flash Pt: 4 °C Storage Temperature: Ambient |
MDL Number:
MFCD00008512 CAS Number: 108-88-3 EINECS: 203-625-9 UN: 1294 ADR: 3,II REACH: 05-2114615130-69 Merck Index: 13,09607 |
Specification Test Results
For Laboratory,Research,or Manufacturing Use |
|
Trace Organic Residues - FID-Sensitive Impurities (as 2-Octanol) Single Impurity Peak (ng/mL) | ≤10 |
ECD Sensitive Impurities (as Heptachlor Epoxide) Single Peak (pg/mL) | ≤10 |
Assay (C₆H₅CH₃) (by GC, corrected for water) | ≥99.7 % |
Color (APHA) | ≤10 |
Residue after Evaporation | ≤1.0 ppm |
Substances Darkened by H₂SO₄ | Passes Test |
Water (by KF, coulometric) | ≤0.03 % |
Learn more
About VWR
Avantor is a vertically integrated, global supplier of discovery-to-delivery solutions for...