You Searched For: Autoradiography Films

The autoradiography films and cassettes detect chemiluminescent labelled samples. These sheets provide maximum clarity and sensitivity, with great signal-to-noise ratios for increased detection effectiveness. Used for storage and transportation of the autoradiography films, the hard cassettes provide light-tight exposures at temperatures down to -70°C. Cassettes provide maximum contact between films and samples, and advanced emulsion technology in the films maximizes image resolution and background clarity.

The autoradiography films and cassettes detect chemiluminescent labelled samples. These sheets provide maximum clarity and sensitivity, with great signal-to-noise ratios for increased detection effectiveness. Used for storage and transportation of the autoradiography films, the hard cassettes provide light-tight exposures at temperatures down to -70°C. Cassettes provide maximum contact between films and samples, and advanced emulsion technology in the films maximizes image resolution and background clarity.


13  results were found

SearchResultCount:"13"

Sort Results

List View Easy View

Rate These Search Results

Supplier: Thermo Fisher Scientific
Description: CL-XPosure™ Film is a clear blue X-ray film recommended for the detection and documentation of blotting assays.

Supplier: CARESTREAM HEALTH
Description: BioMax® MS film is a high performance all-purpose, maximum sensitivity autoradiography film. When used with the BioMax® TranScreen HE intensifying screen it delivers four to eight times greater sensitivity in the detection of ³²P when compared to other autoradiography film and intensifying screen combinations. This film/screen combination is ideal for detection of Northern, Southern and Dot Blotting applications, particularly when detection of low intensity samples or exposure time reduction is required.

New Transparency for European Customers

Have you noticed our new improved visibility on stock location at checkout?

Find out more

Enhancement to stock locations

Supplier: CARESTREAM HEALTH
Description: The BioMax® MS intensifying screen is optimised for use with BioMax® MS film to maximise sensitivity for detection of ³²P and ¹²⁵I labelled samples.

Supplier: CARESTREAM HEALTH
Description: BioMax® MR is a single emulsion film that provides maximum resolution and sensitivity for detection of ³⁵S, ³²P,and ¹⁴C labelled samples. An emulsion coated on a single side of a clear support produces maximum resolution and background clarity in the detection of all labels, making overall reading of sequencing gels easier and more accurate. BioMax® MR film also provides maximum resolution for direct detection of ³²P labelled samples, delivering sharper, crisper band responses that allow viewing in exceptionally fine detail. BioMax® MR film is also suitable for detection of most chemiluminescent labelled samples. Though not as sensitive as BioMax® MS, BioMax® MR film offers maximum resolution and is the recommended film for Western chemiluminescent application where exposures are relatively short.

Supplier: CARESTREAM HEALTH
Description: BioMax® Light is a double emulsion film that provides maximum clarity and sensitivity for detection of chemiluminescent-labelled samples. BioMax® Light produces the highest signal-to-noise ratio of any Kodak film for detection of chemiluminescence. This film performs well with all brands of chemiluminescent kits. BioMax® Light film is suitable for direct and intensifying screen exposures with commonly used isotopes, though it provides lower sensitivity resulting in longer exposure times compared to BioMax® MS, and X-OMAT AR films for radioisotope detection.

Supplier: CARESTREAM HEALTH
Description: Designed for use with gamma emitters such as ¹²⁵I and high-energy beta emitters, such as ³²P, the BioMax™ TranScreen HE intensifying screen offers the greatest sensitivity. When used in conjunction with the BioMax™ MS film, the system equals or exceeds the image quality of conventional autoradiography screen/film systems. By minimising the distances between the radioisotope and phosphor layer, it presents the phosphor to the emitting particles immediately, for less scattering and better spatial resolution.

Catalog Number: (730-3236)
Supplier: CARESTREAM HEALTH
Description: X-OMAT® LS is an economical, blue-tinted film for when the maximum performance of BioMax® MR, BioMax® MS, or X-OMAT® AR film is not required. X-OMAT® LS film is suitable for use with all commonly used radioisotopes and chemiluminescent probes. However, the film provides significantly less detection sensitivity than the BioMax® autoradiography films, resulting in longer exposure times.
UOM: 1 * 50 items


Catalog Number: (GEHE18-1032-27)
Supplier: Cytiva
Description: Autoradiography film, Photographic step tablet
UOM: 1 * 1 items


Supplier: CARESTREAM HEALTH
Description: These micrography films offer considerable latitude in performance and flexibility for most electron microscopy applications. They are suitable for medium-energy electrons (40 to 100 ky) and acceptable results can also be obtained at higher electron levels.

Supplier: CARESTREAM HEALTH
Description: BioMax® XAR Film is an autoradiography film for use with all commonly used isotopes and chemiluminescence labels. The film is coated with emulsion on both sides of a clear base, and is suitable for both direct autoradiography and exposures made with amplification screens, including BioMax® amplification screens.

Supplier: Cytiva
Description: Amersham™ Hyperfilm™ ECL™ is constructed from a clear base coated on both sides with a photographic emulsion that is protected by an anti-scratch layer. The anti-scratch coating reduces the risk of visible artefacts (e.g., plastic wrap marks) and the clear colourless base results in easy reading of images without compromising on sensitivity.

Supplier: Cytiva
Description: Amersham Hyperfilm™ MP is a multipurpose film constructed from a clear base coated on both sides with a photographic emulsion that is protected by an anti-scratch layer. The anti-scratch coating reduces the risk of visible artefacts (e.g., plastic wrap marks) and the clear colourless base results in easy reading of images, without compromising on sensitivity.

Supplier: Cytiva
Description: Storage phosphor screens capture latent images produced by ionising radiation (X-ray, β, and γ emissions from isotopes such as <sup>14</sup>C, <sup>3</sup>H, <sup>125</sup>I, <sup>131</sup>I, <sup>32</sup>P, <sup>35</sup>S, <sup>33</sup>P, and more.). Upon laser-induced stimulation, light is emitted from the storage phosphor screen in proportion to the amount of radioactivity in the sample. The resulting digital image allows for quantitation of subtle signal intensity differences over a wide dynamic range using storage phosphor imaging systems such as Typhoon, Storm, and PhosphorImager. Typically, 50% to 90% less exposure time is required compared with an equivalent exposure to conventional film. Publication quality images are often obtained in a single exposure. They are reusable and are not degraded by repeated exposure to laboratory levels of radioactivity.

Inquire for Price
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the call is still displayed and you need assistance, please call us on +353 1 88 22222.
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the call is still displayed and you need assistance, please call us on +353 1 88 22222
This product is marked as restricted and can only be purchased by approved Shipping Accounts. If you need further assistance, email VWR Regulatory Department at eurega_services@eu.vwr.com
-Additional Documentation May be needed to purchase this item. A VWR representative will contact you if needed.
This product has been blocked by your organisation. Please contact your purchasing department for more information.
The original product is no longer available. The replacement shown is available.
Product(s) marked with this symbol are discontinued - sold till end of stock. Alternatives may be available by searching with the VWR Catalog Number listed above. If you need further assistance, please call VWR Customer Service on +353 1 8822222.
1 - 13 of 13
no targeter for Bottom